Online UPS with inbuilt Galvanic isolation Single Phase

6KVA-10KVA3:1 PhaseTrue Online Double Conversion UPS

Description

The Champion True Online Double Conversion UPS is designed to provide 100% voltage conditioning. It rectifys AC mains into a DC voltage which is connected to an inverter input to provide a clean AC sinewave waveform for the UPS output. These UPS operate continuously, regardless of what happens to the commercial AC power source and provide protection during untimely power outages. By continually supplying your critical load with near perfect AC Power, it prevents damaging power line abnormalities from reaching your sensitive equipment. Our carefully engineered design will extend equipment life and reduce costly hardware failures. Our custom built UPS are available in a wide variety of power ratings, configurations and designs to meet the requirements of your installation.

Features

  • True on-line topology
  • Three phase input - Single phase output
  • Smart Computer Interface
  • DSP Microprocessor Control
  • User-friendly Compact Design
  • Input Power Factor Corrector
  • Built in Automatic & Manual Bypass
  • IGBT Module and Latest PWM Technology
  • Wide Input Voltage Range & Generator Compatible
  • Built-in High Capacity Charger for Long Backup Time
  • DC Start & Automatic Self-diagnostic Function
  • Full Protection: Overload, Short-circuit, Over Temp. etc.

Applications

  • Data Centers
  • Server & Network
  • Telecommunication Equipment
  • Large Network Switches
  • Financial Institution
  • Emergency Services
  • Medical Equipment
  • Security Systems
  • Industrial & Manufacturing
  • Power / Oil / Gas

Technical Specification

Models UPS-8KVA UPS-10KVA UPS-15KVA UPS-20KVA
Power
Capacity 5600W 7000W 10500W 14000W
Input
Input Voltage 304VAC - 478VAC
Input Frequency 46Hz - 54 Hz
Phase Three Phase with Ground
Input Power Factor >0.95
Output
Voltage ~230VAC ± 1%
Frequency Synchronized 46-54Hz (Line Mode) 50Hz ± 0.1% (Battery Mode)
Waveform Pure Sine Wave
Distortion <3% for Linear Load; <5% for Non Linear Load
Power Factor 0.7
Overload Capacity 105% ~ 120% for 10 min
Crest Factor 3:1
Batteries
Type External Battery Bank
DC Voltage 192-240VDC
Recharging Time 8 Hours to 90% of full capacity after full load discharge
Charger Type Constant Voltage & Current
Charging Voltage 218 - 274VDC ± 1%
Efficiency
Overall > 90%
Inverter > 92%
Protections
Mains I/P Under & Over Voltage cut-off, Phase reversal
Inverter Output Overload / Short-circuit / Output Under Voltage / Battery Low
Alarms & Indications
Audible Alarm Battery Mode, Battery Low, Overload, Fault
LED & LCD Display Load/Battery Level, Utility Power, Inverter, Bypass, Overload, Fault
Physical
MCB’s Battery / Input
Cooling Forced Air
Dimension (W×D×H)(mm) 500×260×540 717×260×570
Net Weight (w/o battery) 32 kgs 55 kgs
* Specifications are subject to change without any prior notice.